EICR TESTING · BRISTOL & SOUTH BRISTOL

EICR testing in Bristol

EICR Bristol: Electrical Installation Condition Reports for landlords, homeowners and homebuyers across the city. Fixed, published prices, an unhurried inspection and a plain-English report emailed to you.

NAPIT Approved TrustMark Trading Standards Approved
★★★★★ on Google
Fixed prices from £200 + VAT ↓
Remedials quoted fairly
Bristol Phoenix Group electrician testing a consumer unit during an EICR inspection in Bristol
● EICR inspection under way in Bristol

What your EICR covers

An EICR is a full health check of your fixed electrical installation. Ours are done properly: no rushed sampling, no invented faults, and every observation explained in plain English. If you are wondering what EICR actually stands for, our guide covers it.

  • ✓Fuse board inspected and tested, including RCD protection and condition
  • ✓Circuits tested for earthing, polarity, insulation and disconnection times
  • ✓Sockets, switches and accessories checked for damage, wear and safe wiring
  • ✓Every observation coded and explained: C1, C2, C3 and FI in plain English
  • ✓Certificate emailed promptly, ready for tenants, solicitors or your records

Electrical testing and inspection. An EICR is the formal electrical testing and inspection of your whole installation, often called a periodic inspection. We also carry out general testing and inspecting, from wiring checks to socket and switch inspections. The power only goes off briefly, circuit by circuit, while each one is tested, and we work around anything that must stay on if you tell us in advance. Tripping RCDs, dead sockets or flickering lights are a fault rather than an inspection: see our electrical fault finding page.

Who needs one

Landlords: a satisfactory EICR at least every 5 years is a legal requirement for rented homes in England under the Electrical Safety Standards in the Private Rented Sector Regulations, with a copy to tenants within 28 days.
Homebuyers and sellers: a pre-exchange EICR tells you exactly what you are buying, before it becomes your problem.
Homeowners: Electrical Safety First recommends a check at least every 10 years, or sooner for older installations and before major work.
Businesses: offices, shops and commercial units are covered on our commercial EICR page.

EICR cost in Bristol: fixed, published prices

Priced by bedrooms, flat or house. Fixed prices, no hourly meter. The price we agree is the price you pay.

PROPERTYPRICE
Studio or 1-bed home£200 + VAT (£240 inc VAT)
2-bed home£225 + VAT (£270 inc VAT)
3-bed home£250 + VAT (£300 inc VAT)
4-bed home£300 + VAT (£360 inc VAT)
5-bed home£350 + VAT (£420 inc VAT)
6-bed+ homesfrom £400 + VAT confirmed before booking
HMOsfrom £350 + VAT confirmed before booking

Standard scope: one consumer unit, up to 12 circuits, single-phase. Extras if they apply, always agreed first: each additional consumer unit (for example a garage or flat sub-board) +£50, outbuilding tested on the same visit +£50, +£15 per circuit beyond 12, three-phase from +£75 (all + VAT). Any remedial work is quoted separately. See our guide to what an EICR costs and why.

Seen a much cheaper EICR advertised? Ask two questions: how long will they spend on site, and how many circuits do they actually test? We allow one to two hours for smaller homes and around two hours for a typical 3 or 4-bed, test properly, and never invent remedial work to make up for a cheap certificate.

What happens on the day

Usually two of us on site, so the inspection is thorough without taking your whole day.

1 · WE TEST PROPERLY

Fuse board, circuits and accessories, inspected and tested without rushing. Power is off in short bursts and we work around you.

2 · PLAIN-ENGLISH REPORT

Your certificate is completed carefully after the visit and emailed to you, with every C1, C2, C3 and FI code explained so you know exactly where you stand.

3 · REMEDIALS QUOTED FAIRLY

If anything needs putting right, you get a separate itemised quote. No pressure, and you are free to use anyone you like for the fixes.

Landlord renewals: we can diary your 5-year date and remind you when it is due. We are NAPIT registered and based in South Bristol, covering the whole city. Call 0117 2447 382 or contact us to book your EICR.

Understanding your EICR codes: C1, C2, C3 and FI

Every observation on your certificate gets one of four classification codes, set out in the Electrical Safety First best practice guide. Here is what each one means for you.

C1 · DANGER PRESENT

A risk of injury is present right now. C1 observations need immediate remedial action, and we tell you on the day rather than waiting for the written report.

C2 · POTENTIALLY DANGEROUS

Not dangerous yet, but it would become so if a fault occurred or circumstances changed. C2 observations need urgent remedial action and, like C1, make the report unsatisfactory.

C3 · IMPROVEMENT RECOMMENDED

Neither an immediate nor a potential danger. C3 items are recommendations, not failures, and do not make an EICR unsatisfactory on their own.

FI · FURTHER INVESTIGATION

Used when we cannot confirm an observation is safe without investigating further, for example opening up a section of the installation that was not accessible on the day.

A satisfactory EICR has no C1 or C2 observations. If yours does, we quote the remedial work separately and itemised, and you are free to use anyone you like to carry it out.

What Bristol customers say

★★★★★  Rated 5 stars on Google
★★★★★
"Great quality work, punctual and very clean. Highly recommend."
James · Google review
★★★★★
"Great professionalism and clear communication. Luke was able to get us booked in the same week."
Siobhan A · pre-exchange EICR
★★★★★
"The most reliable and knowledgeable electricians I've come across. Extremely professional."
Emma · full house renovation

Frequently asked questions

How much does an EICR cost in Bristol?

Our prices are fixed and published, and the same for a flat or a house: £200 + VAT for a studio or 1-bed, £225 + VAT for a 2-bed, £250 + VAT for a 3-bed, £300 + VAT for a 4-bed and £350 + VAT for a 5-bed. Homes with 6 or more bedrooms are from £400 + VAT and HMOs from £350 + VAT, both confirmed after a quick chat. The price we agree is the price you pay.

How long does an EICR take?

We allow 1 to 2 hours for smaller homes and around 2 hours for a typical 3 or 4-bed house, with two of us on site for most visits. We finish the certificate afterwards and email it to you, so you are not waiting around.

Is an EICR a legal requirement?

For rented homes in England, yes: landlords must have a satisfactory EICR at least every 5 years, give tenants a copy within 28 days of the inspection, and show new tenants the report before they move in. For owner-occupied homes it is not law, but an inspection roughly every 10 years is the standard recommendation.

What happens if my EICR is unsatisfactory?

The report will list observations coded C1, C2, C3 or FI. C1 and C2 items make the report unsatisfactory and need putting right; C3 items are improvements, not failures. We explain every code in plain English and quote remedial work separately, itemised, and you are free to use anyone you like for the fixes.

How often should an EICR be done?

Every 5 years for rented property, roughly every 10 years for an owner-occupied home, and sooner if you are buying, selling, taking on tenants, or the installation has visible problems.

Do I need an EICR to sell or buy a house?

It is not a legal requirement, but buyers, solicitors and mortgage lenders increasingly ask. A pre-exchange EICR tells you exactly what you are buying and is far cheaper than discovering problems after completion.

What do the C1, C2, C3 and FI codes on my report mean?

C1 means a danger is present and needs immediate action. C2 means it is not dangerous yet but would become so, and needs urgent action. C3 is a recommended improvement, not a fault. FI means we need to investigate further before we can classify it. Only C1 and C2 make a report unsatisfactory; see our code-by-code breakdown above.

What if my property has more than one fuse board or an outbuilding?

It is common in extended or converted homes. Each additional consumer unit, such as one for a garage, annexe or flat sub-board, adds £50 + VAT, and testing an outbuilding on the same visit is another £50 + VAT. We agree any extras with you before we start, so there are no surprises on the invoice.

Get your EICR quote

A few quick details and we'll come back to you with next steps. Prefer to talk? Call 0117 2447 382
Fields marked * are required. Got photos? Email them to info@bristolphoenixgroup.co.uk, they really help.

What do you need? *

Consent *

TrustMark Government Endorsed Quality, Trading Standards Approved

TrustMark Registered Business and Trading Standards Approved, licence no. 4257835. TrustMark is the Government Endorsed Quality Scheme for work in and around the home, and Trading Standards has also checked and approved us under TrustMark's Trading Standards Approved scheme. We are registered for domestic electrical work through NAPIT, our scheme provider. Check our registration on TrustMark