If you have ever looked at a consumer unit, an EICR, or a box of spare breakers and wondered what “BS number for RCBO” actually means, the short answer is BS EN 61009-1. That is the British Standard every RCBO fitted in a UK home or small business has to meet. It is also the figure that goes in the “BS (EN)” column on your electrical certificate, and the reason some older Bristol consumer units get flagged on an inspection. Here is what it means in practice, and when it actually matters for your home, your rental, or your paperwork.
What is the BS number for an RCBO?
An RCBO (residual current operated circuit breaker with overcurrent protection) combines two jobs in one device: it trips on a fault current like a normal circuit breaker, and it trips on an earth leakage like an RCD. The British Standard that covers RCBOs for household and similar use is BS EN 61009-1, currently the 2012 edition with Amendment 13 (2021), as published by BSI, the UK’s national standards body. It sets out the general rules for how the device is built, tested, and rated.
You will usually see this number printed in small type on the front or side of the device itself, and it is the figure an electrician writes into the “BS (EN)” column for the overcurrent device and the RCD on the official IET model Electrical Installation Condition Report. We see that column queried a lot, usually by a landlord or a homeowner reading their own EICR for the first time.
RCBO, MCB or old fuse: the standards side by side
Three different devices tend to come up in the same conversation, and they are not interchangeable:
| Device | British Standard | What it protects against |
|---|---|---|
| RCBO | BS EN 61009-1 | Overload, short circuit and earth leakage (combined) |
| MCB (no RCD) | BS EN 60898-1 | Overload and short circuit only |
| Old rewireable fuse | BS 3036 | Overload and short circuit only, no earth leakage protection, slower to react |
A board full of plain MCBs to BS EN 60898-1, with no RCD or RCBO protection at all, is still fairly common in Bristol terraces that have not been touched since the 1990s. A board of BS 3036 rewireable fuses is older still, and usually gets a C2 or C3 coding on inspection rather than an outright fail, though most owners choose to replace it anyway once they understand what it is missing.
Why the amendment to BS 7671 pushed more boards toward RCBOs
The 18th Edition wiring regulations were updated by Amendment 2 in 2022. Two changes are the main reason RCBO boards are now the normal specification rather than the upgrade option:
- Regulation 411.3.3 requires 30mA RCD protection on almost every socket circuit used by ordinary people, and on outdoor sockets and mobile equipment up to 32A.
- Regulation 531.3.2 restricts the older Type AC device to purely resistive loads with no DC component, which in practice makes Type A the realistic minimum on most circuits, and names RCBOs as the standard alternative to a split load board.
Put together, that is most of a modern consumer unit covered by a device to BS EN 61009-1 rather than a shared RCD protecting half the board. It is also why a split load board from fifteen years ago, perfectly legal when it was fitted, looks dated against current practice.
What we fit in Bristol, and why it is already BS EN 61009-1
Every consumer unit we install carries an RCBO to BS EN 61009-1 on every single circuit, not just the sockets, plus surge protection as standard. That is a high-integrity specification: one faulty circuit trips on its own, the rest of the house stays live, and the certificate we hand over already has the right BS (EN) number against every device, with no ambiguity for the next inspector.
Our published consumer unit prices, all plus VAT:
- 6-way board (flats and small homes): £680
- 8 to 12-way board, the size most houses need: £780
- 15-way board: £920
- Larger boards and three-phase: from £1,195, after a survey
For context, UK-wide cost guides put a full RCBO board with surge protection, supplied and fitted, at roughly £550 to £800 outside London and £850 to £1,100 in London and the South East, against £450 to £700 for a standard split load board doing less. Separate trade pricing puts the RCBO equipment itself at around £150 to £350 within a fitted job costing £450 to £1,200 in total once labour, testing and certification are included. Our fixed prices sit comfortably inside that range and cover a board that already meets the higher specification rather than the minimum one.
How to read the other markings on an RCBO
The BS number is only one of the markings on the front of the device, and if you are trying to match a replacement to what is already in your consumer unit, the others matter just as much:
- Current rating, shown in amps, such as 6A, 16A, 32A or 40A. This has to match the circuit it protects, not just fit the slot.
- Trip curve, usually B or C, printed just before the amp rating. B trips at a lower overload multiple and suits most domestic lighting and socket circuits; C allows a higher inrush and tends to show up on circuits with motors or transformers.
- Sensitivity, almost always 30mA on a domestic RCBO, which is the figure behind the earth leakage protection.
- Breaking capacity, shown in kA, which is how much fault current the device can safely interrupt without failing itself.
- Type, shown as a small symbol for AC, A, F or B. Type A is now the practical minimum on most circuits under BS 7671 Amendment 2, and Type A is what we fit as standard.
Buying a device with the right BS number but the wrong curve, rating or type is one of the more common mistakes we see corrected on an EICR, which is a large part of why board work is notifiable and why we would always want to see the existing board before quoting, rather than matching blind from a part number.
Where this matters in South Bristol
A lot of the housing stock in Bedminster, Knowle, Bishopsworth and the other South Bristol streets we work in dates from the 1900s to the 1930s. Many of those homes have been rewired at some point, but the consumer unit itself often lags behind: a plastic board with a handful of MCBs and one shared RCD, or in older cases a rewireable fuse board that has quietly outlived several owners. Neither will carry a BS (EN) number that matches current RCBO practice, and that is one of the first things we flag on a landlord EICR or a homebuyer survey.
For rented property specifically, an EICR that shows the wrong or missing BS (EN) detail against a protective device is a prompt to get it looked at properly rather than something to argue past. Landlords have a legal duty to act on EICR findings, and a straightforward board upgrade is usually the fix. We see the same pattern across HMOs in Bedminster and Knowle, where the extra sockets and appliances added over the years were often wired back into a board that was never upgraded to match.
Signs your board is overdue an upgrade
- Your consumer unit has a row of switches with no separate RCD or RCBO markings at all.
- One RCD covers half the house, so a fault in the kitchen trips the lights upstairs too.
- The board still has ceramic or cartridge fuse carriers rather than clip-in breakers.
- Your last EICR recorded a C2 or C3 against the consumer unit or its protective devices.
- You are adding circuits, such as an EV charger or a new kitchen, and want them on dedicated RCBOs rather than sharing an existing RCD.
Frequently asked questions
What is the BS number for an RCBO?
BS EN 61009-1. It is the British Standard that covers residual current operated circuit breakers with integral overcurrent protection for household and similar use, currently the 2012 edition with Amendment 13 (2021).
Is an RCBO the same as an MCB?
No. An MCB (BS EN 60898-1) only protects against overload and short circuit. An RCBO (BS EN 61009-1) does that and adds earth leakage protection in the same device, which is why it needs its own, separate standard.
Can I fit or replace an RCBO myself?
Work on a consumer unit is notifiable under Part P of the Building Regulations in England, and it needs to be tested and certified afterwards. We would always recommend using a registered electrician rather than opening the board yourself, both for safety and so the paperwork is in order if you come to sell or let the property.
Do all circuits in my house need an RCBO?
Not by law on an existing installation, but it is the specification we fit as standard on every new board because it gives better fault isolation and meets current practice under BS 7671 Amendment 2. An EICR on an older board without this will usually carry an observation rather than an automatic fail.
Will my EICR fail if my consumer unit is not BS EN 61009-1?
Not automatically. An inspector records what is actually fitted and codes any shortfall, typically C3 (improvement recommended) for an older but working board, rising to C2 if protection is genuinely inadequate. The BS (EN) column simply records what standard the existing devices meet, so the inspector and any future reader of the certificate know exactly what is in the box.
How much does a BS EN 61009-1 consumer unit cost in Bristol?
Our fixed prices start at £680 plus VAT for a 6-way board and £780 for the 8 to 12-way board most houses need, with larger and three-phase boards quoted after a short survey. Every board we fit has an RCBO to BS EN 61009-1 on each circuit as standard, with surge protection included.
What does the curve type, such as B or C, mean on an RCBO?
It describes how quickly the device trips on an overload, rather than the earth leakage side. Type B suits most domestic lighting and socket circuits and is what we fit as standard, while Type C allows a brief higher inrush and tends to appear on circuits feeding motors or transformers.
Can I buy a BS EN 61009-1 RCBO on its own, without a new board?
You can buy one, but fitting it into an existing consumer unit is notifiable electrical work under Part P and needs to be tested and certified once it is in. If a single circuit keeps tripping or a device has failed, it is usually worth having an electrician look at the whole board while they are there, rather than swapping one device in isolation.
Get a compliant consumer unit fitted in Bristol
If your EICR has flagged the consumer unit, or you just want a board where every circuit has its own RCBO to BS EN 61009-1 and a certificate to match, get in touch for a free written quote. We are NAPIT approved and TrustMark Trading Standards Approved, based in South Bristol, and every consumer unit we fit is tested, certificated and notified. Have a look at our full range of electrical services in Bristol, including consumer unit replacement, EICR certificates, and our page explaining what a consumer unit actually is if you want the fuller picture before you book. Full pricing for every service is on our electrician prices page.